1The pre-installed sediment filter for the water softening equipment provides excellent protection for the water softening equipment in water-using scenarios with a large amount of sediment, significantly reducing the failure rate of the water softening equipment.2The water softening equipment uses flow-type control valves, which not only save salt but also ensure the quality of the effluent3The resin added to the water softening equipment complies with the power standard and has a better softening capacity for high-hardness water than the national standard resin.4We provide soft water hardness specifically designed for steam boilers in conjunction with water softening equipment......
EMAIL:bjyuanlai@163.com1The pre-installed sediment filter for the water softening equipment provides excellent protection for the water softening equipment in water-using scenarios with a large amount of sediment, significantly reducing the failure rate of the water softening equipment.
2The water softening equipment uses flow-type control valves, which not only save salt but also ensure the quality of the effluent
3The resin added to the water softening equipment complies with the power standard and has a better softening capacity for high-hardness water than the national standard resin.
4We provide a special soft water hardness indicator for steam boilers to match the soft water equipment. There is no need for dedicated laboratory personnel. The boiler operator can directly test whether the soft water is qualified to ensure that the water used in the boiler is qualified soft water.
5As a supplier of water softening equipment, we have a high-quality technical team that can provide customers with reasonable water softening equipment designs and scientific installation plans. After the installation is completed, we will conduct thorough training for customers. For various problems encountered by users during the use of water softening equipment, our technical team offers answers and timely and effective on-site services Ensure that customers have no worries when using the water softening equipment.
6We have a spare parts warehouse for a series of water softening equipment and pure water reverse osmosis equipment, which can provide convenient maintenance services for our customers. Water softening treatment for enterprises and institutions such as boiler rooms, heating stations, hotels, office buildings, cold storage facilities, shopping malls, power plants, steel mills, dyeing and printing factories, etc. The fully automatic water softener removes water by using the principle of ion exchangeCa2+,Mg2+Ions are used to achieve the purpose of preventing and inhibiting scale formation. The control system of the series of fully automatic water softeners adopts centralized multi-way valve control and control components. The valve body is made of engineering plastic material, which is sturdy and lightweight. The structure is exquisitely designed, simple and reasonable, easy to disassemble and maintain. Resin tanks are available with options of anti-corrosion materials such as wound fiberglass reinforced plastic, carbon steel or stainless steel lining. The salt tank isPE(Polyethylene)The material is small in size, light in weight, corrosion-resistant and easy to install.
Ii. Product Features
Automation of water softening process: Introduced to the United StatesAutotrolThe controller, through the synchronous motor drive program control device, realizes the automation of the entire process of ion exchange and resin regeneration. Just add the regenerant regularly, and continuous or intermittent water supply can be achieved under fully automatic conditions.
2. The overall design of the water softener is reasonable, enabling the effective working exchange capacity of the resin to be fully utilized.
3. Stable water output: USAAutotrolThe controller can accurately control the flow rate, regeneration time and the degree of each regeneration stage to ensure the stability of the effluent.
4. Labor-saving: No need for dedicated personnel to stand by. Easy to install. It can be installed and used on the same day.
5. Water-saving: The water production rate of the water softener has reached98%That's all.
6. Energy-saving: It adopts the siphon regeneration principle and does not require a salt pump. Its power consumption is only equivalent to that of manual water softening equipment 1%.
7. Small floor space: Only the floor space of the resin tank and the salt tank needs to be provided, saving the space occupied by pipelines and salt pumps.
8. Convenient adjustment: Users can adjust the regeneration cycle and regeneration time according to their actual situation and needs by themselves.
9. It adopts electronic control mode and has a power-off memory function. It can query historical records such as peak water production time and total cumulative water production volume, and analyze water usage. Low operating costs Due to its high degree of automation, the softener can adapt to changes in water volume, accurately measure the water production volume, and precisely measure the amount of regenerant used, avoiding the unnecessary waste of regenerant during regeneration and saving a large amount of labor costs at the same time.
1. The foundation needs to be level, and a common cement surface is fine. There should be a floor drain or drainage ditch near the water softener.
2. Raw water hardness<8mmol/L(namely400mg/LIf the hardness is greater than8mmol/LPlease make a declaration in advance).
3. Inlet water pressure: Maintain continuous pressure0.2~0.6Mpa(It includes the water production process and the regeneration process)(Such as<0.2MpaA pipeline pump must be added); When the incoming water pressure is insufficient(Or when there is no constant pressure)A pressurizing pump needs to be equipped, but the on and off of the pump must be controlled. Generally, the control of a pump requires two types of signals: one is the liquid level height signal of the softened water tank, and the other is the signal indicating whether the control valve is undergoing a regeneration process. Therefore, when users need water from the water supply pump, please declare in advance and our company will provide special supply.
4. Operating temperature2~50℃.
5. Power supply220V 50Hz.
6. Before the raw water enters the water softener, users should addYThis type of filter prevents impurities in water from blocking the valve body.
7. A pressure gauge should be installed on the water inlet pipeline, and a bypass valve should be installed between the inlet and outlet pipelines.
8. If the user has any other requirements for the installation and supply of the equipment, please specify them clearly in the contract.